Wireless Sensor 2 Battery Banks, Voltage & Current
2 battery banks voltage & current
*Requires 0-50 mV shunt. One per battery.
Specifications:
- Status LEDs: Blinking green — Power ON / Intermittent blue sensor — Sending data
- Operating Voltage: 9 – 30 Vdc
- Range: Up to 300 ft
- Power Consumption: 11 mA @ 12 Vdc
- Battery (Back Up) — Optional: 1,100 mAh / Lithium Thionyl Chloride
- Battery Backup Time: Up to 100 hrs
- Wireless Frequency: 900 MHz
- Enclosure: IP-66 Rated ABS Plastic
- Operational Temperature: -22°F – 167°F / -30°C – 75°C
- Humidity: 95% R.H. @ 122°F / 50°C non condensing
- Compact Size: 4 in x 2.75 in x 1.6 in / 102 mm x 70 mm x 40 mm
- Light Weight: 5 oz / 141 grams
- Certifications: FCC, CE